The Series  ’HAC - F ’ Ventilation Air Flue Damper, is designed to save energy by stopping the escape of warm air up the chimney vent while the heating appliance is not firing and is interlocked to be open during firing.

The HAC-F - VENTILATION FLUE AIR CONTROL DAMPERS are also designed with a 10% bypass to allow for a minimum escape of air during the off cycle of firing. Nylon bearings and all wiring are mounted 1" away from the heated part of the damper to prevent the effects of excess heat. These dampers are also designed for years of trouble free service.

The 4" -  12" models are CSA International Certified .  

Other sizes are also to be installed according to good engineering practice acceptable to authorities having jurisdiction.


Satisfaction guaranteed.


HAC - F - Flue Damper

HAC - F - Flue Damper
4" - 9" in Diameter
CSA Certified


  HAC - F - Larger Sizes 
with Belimo Actuator
 TFB24 (24Vac/dc) or TFB120 (100 - 240Vac)
10" - 30" in Diameter
CSA Certified up to 12" in Diameter

HAC-0x11-SPC - F
General Information Sheet -pdf

HAC - xx41 - SPC - F
General Information Sheet -pdf

x = Diameter in Inches
P C
 = Power Closed Damper
S  = indicates End Switch

HAC-0x1 1 -OPO <- the " 1" in indicates an added relay


Photos of HAC - F - Larger sizes
 

Up to 30" in diameter 
with Belimo Actuators.


*General Damper Identification : i.e. HAC - 0611 - SPC - F (Special for Flue Damper)

Series
Diameter (in)
Motor  Type
Relays
End Switch
Power Closed
Flue Damper
HAC  
06  
1  
1  
S  
PC  
F


Features Include:  
  • Easy to install in-line as part of standard air duct.
  • Durable, patented  HMI   HOYME 'spring motor drive' with nylon bearings.
  • 26 ga. galv. steel from 4" to 5" dia.; 24 ga. galv. steel from 6" to 9" dia.; 24 ga. galv. re-enforced steel from 10" to 14" dia.; 22 ga. galv. re-enforced steel from 16" to 18" dia.: Other sizes and weight of steel upon request.
  • These dampers are interlocked to the appliance and are CSA certified (4" - 12") .

    See   HMI   Interface Relay Adaptors   to interface with 250mVdc - 100Vdc and 120Vac Safety control systems specially designed for these dampers.


HAC-F Wiring Diagrams

SCHEMATIC WIRING DIAGRAM OF FLUE 
DAMPER and APPLIANCE TRANSFORMER.
 



SCHEMATIC WIRING DIAGRAM OF FLUE 
DAMPER CONNECTED TO A 24Vac SAFETY CIRCUIT AND AN AUXILIARY TRANSFORMER.



Other options that may be used:  
  • Using Stainless Steel instead of galv. steel.
  • Other Belimo Actuators like FSLF-24 US or FSLF120US