Question:
*
Why can't I use a regular universal motorized damper (HAC) to control the cold air coming from my combustion air duct?
*

This universal motorized 24Vac Fresh Air Control Damper , Series HAC , fastens to an air duct in-line to control the flow of air, partially or completely, depending on its mechanical setting.
This damper may be ordered with one motor, MS10A Actuator (replaces previous two motor model) or a Belimo actuator.


    CSA International Certified (up to 12"Ø).
Satisfaction guaranteed.


HAC - One Motor

HAC - One Motor
(with mounting collar)   

HAC - MS10A


HAC - MS10A Actuator
(replaces old two motor model)
HAC - Belimo Actuator

HAC - Belimo Actuator

HAC - H - Fresh Air Damper for Heat

HAC - H
- Fresh Air Damper for Heat -
HAC - One Motor-No Collar

HAC - One Motor
(without mounting collar) 

HAC - MS10A Actuator


HAC - MS10A Actuator
(replaces old two motor model)
HAC - Belimo Actuator

HAC - Belimo Actuator

HAC - H - Fresh Air Damper for Heat

HAC - H
- Fresh Air Damper for Heat -
4" - 9" in Diameter 6" - 12" in Diameter 8" - 20" in Diameter Motor and controls are mounted
1" away from Damper body
HAC-0x10-OP*
HAC-0x10-SP*
HAC-0x11-OP*
HAC-0x11-SP*
HAC-0x50-OP*
HAC-0x50-SP*
HAC-0x51-OP*
HAC-0x51-SP*
Various Belimo Actuator models may be ordered

HAC - H - Larger sizes
Over 20" in diameter
with Belimo Actuators.
HAC-0x10-OP* - H
HAC-0x10-SP* - H
HAC-0x11-OP* - H
HAC-0x11-SP* - H

HAC-0x50-OP* - H
HAC-0x50-SP* - H
x = Diameter in Inches
* = P
O - Power Open or P C - Power Closed Damper
S P* = includes End Switch
O P* = No End Switch
HAC-0x1 1-OPO <- the " 1" in this position indicates an added relay, a " 0" indicates no relay


*General Damper Identification : i.e. HAC - 0611 - SPC - H (Special for heat)

Series
Diameter (in)
Motors
Relays
End Switch
Power Open/Closed
Special for heat
HAC
06
1
1
S
PC
H


Features Include:
  • Easy to install in-line as part of standard air duct.
  • Durable, patented HMI  HOYME 'spring motor drive' with nylon bearings.
  • 26 ga. galv. steel from 4"Ø to 5"Ø.
    24 ga. galv. steel from 6"Ø to 9"Ø
    24 ga. galv. re-enforced steel from 10"Ø to 14"Ø
    22 ga. galv. re-enforced steel from 16"Ø to 18"Ø
    Other sizes and weight of steel upon request.
  • 8"Ø dampers and smaller are 8" in length
    9"Ø dampers are 9" in length
    10"Ø dampers are 10" in length
    11"Ø dampers and larger are 11" in length
  • 9"Ø dampers include a single reinforcement band
    10"Ø dampers and larger include two reinforcement bands
  • These dampers can be used for the new ventilation code which requires a designated exhaust fan, a centrally located switch marked 'VENTILATION' and a fresh air intake damper, all interconnected to the furnace circulation fan.
    See
    HMI 
     Interface Relay Adaptors'  which have been specially designed for these dampers and new ventilation codes.



Other options that may be added:


HAC
Make-up Air Installation
HAC - Make-up Air Damper Installation with a Forced Air Furnace and HOM - Combustion Air Damper
HAC and HOM installed with a Forced Air Furnace
HAC damper is pictured in green.
HAC- Make-up air Installation
HAC
Humidifier Installation
HAC - Humidifier Installation
HAC
Zone Air Installation
HAC - Zone Air Installation



Colored Wiring Diagrams used with HAC- Series

#2A. Combustion air damper for two furnaces and one replacement air damper
#2A1. Combustion air damper for two furnaces and two replacement air dampers
#2B. Combustion air damper for two furnaces and two replacement air dampers
#2B1. Combustion air damper for two furnaces and two replacement air dampers
#3. Combustion air damper and replacement air damper, Power Close
#3A. Combustion air damper and replacement air damper, Power Open
#3A1. Combustion air damper and replacement air damper, Power Open with switch
#3A2. Combustion air damper and replacement air damper, Power Open with Hoyme Switch
#3A3. Combustion air damper and replacement air damper, Power Open with timer/switch
#4. Replacement air damper opens during firing, Power Close with Relay 
#4A. Forced Air Furnace and a replacement air damper, Power Open
#4A1. Forced Air Furnace and a replacement air damper, Power Open
#4A2. Forced Air Furnace and a replacement air damper, Power Open
#4A3. Forced Air Furnace and a replacement air damper, Power Open
#5. 120Vac vent switch, combustion air, and replacement air
#5A. 120Vac vent switch, combustion air and replacement air(2 furnaces)
#5B. 120Vac vent switch, combustion air(2 furnaces), replacement air
#5B1. 120Vac vent switch, combustion air(2 furnaces), replacement air dampers with relays
#5C. 120 Vac two double pole vent switches with two exhaust fans , combustion air and replacement air
#6. 120Vac vent switch, Adaptor 1101 and replacement air damper, Power Close, opens during firing
#6A. 120Vac vent switch, Adaptor 1101 and replacement air damper, Power Open
#6A1. Two 120Vac separate double-pole vent switches and fans, Adaptor 1101 and replacement air damper, Power Open
#6A2. Two 120Vac seperate double-pole vent switchs and fans, Adaptor 1101 and replacement air damper, Power Close
#6A3. Combustion Air, Two 120Vac separate vent switchs and fans, Two Adaptor 1101's & replacement air damper, Power Close
#6A4. Two 120Vac separate vent switchs and fans, an Adaptor 1101-05A & an 1102-TWP, replacement air damper, Power Close
#6A5. Two 120Vac separate vent switchs and fans, an Adaptor 1101-05A & an 1102-TWP, replacement air damper, Power Open
#6B. Economizer Circuit System to Ventilate a Computer Server Room
#6C. Vent switch, replacement air - power closed, interlocked with exhaust fan
#6C1. Vent switch, replacement air - power open, interlocked with exhaust fan
#6C2. Vent switch, replacement air - power open, interconnected with exhaust fan, heating cycle and/or cooling cycle.
#7. 24Vac vent switch, combustion air, and replacement air
#7A. 24Vac vent switch, combustion air, and replacement air with two exhaust fans and two individual timers
#7A1. 24Vac vent switch, combustion air, and replacement air with two exhaust fans and two individual timers Power open
#8. 24Vac vent switch and replacement air opens during firing
#8A. 24Vac vent switch and replacement air damper Power Open
#8A1. 24Vac vent controlled by switch and replacement air damper Power Open
#8A2. Replacement air damper Power Open with 120Vac plug-in vent fan and dampers controlled by vent switch
#8A4. Forced Air Furnace having a combustion air supply duct and also a replacement air duct(PC) serving as an air supply for a 120Vac gas dryer.
#8A5. Forced Air Furnace having a combustion air supply duct and also a replacement air duct(PO) serving as an air supply for a 120Vac gas dryer.
#8A7. Forced Air Furnace having a MAC air supply duct and also a replacement air duct(PC) serving as an air supply for a 120Vac gas dryer.
#8A8. Forced Air Furnace having a MAC air supply duct and also a replacement air duct(PO) serving as an air supply for a 120Vac gas dryer.
#8B. 24Vac vent switch with relay, replacement air damper Power Closed
#8B1. 24Vac vent switch with relay, replacement air damper Power Close with exhaust fan
#8C. Two Forced Air Furnaces sharing a replacement air supply duct controlled by one fresh air damper with Power Closed Damper
#8C1. Two Forced Air Furnaces sharing a replacement air supply duct controlled by one fresh air damper with Power Open Damper
#8C2. Two Forced Air Furnaces sharing a replacement air supply duct controlled by one fresh air damper with Power Open Damper
#8C3. Two Forced Air Furnaces sharing a replacement air supply duct controlled by one fresh air damper with Power Open Damper
#8C4. Two Forced Air Furnaces sharing a replacement air supply duct controlled by one fresh air damper with Power Open Damper
#8D. Two Forced Air Furnaces sharing a replacement air supply duct controlled by one fresh air damper with Power Close Damper
#8D1. Two Forced Air Furnaces sharing a replacement air supply duct controlled by one fresh air damper with Power Open Damper
#9. Timer, vent switch, combustion air, and replacement air
#9A. Timer, vent switch and replacement air
#9A1. Timer, vent switch, and replacement air damper, Power Open
#9A2. Timer adaptor combined with 1101 Adaptor
#9A3. Plug-in exhaust fan controlled by a designated ventilation switch and automatic interval timer
#9A4. 120Vac Vent Fans, Vent Switch, Timer Adaptor with 1102-TWP Adaptor, Replacement air damper (Power Open)
#9A5. 120Vac Vent Fans, Vent Switch, Timer Adaptor with 1102-TWP Adaptor, Replacement air damper (Power Close)
#9B. Timer, 3-way vent switch and replacement air
#9B1. Timer, vent switch, replacement air damper, Power Open and a 3-way ventilation switch
#9C. Timer, vent switch, replacement air, Power Close, and an exhaust fan with 3-way ventilation switch
#9C1. Timer, vent switch, replacement air, Power Open, and an exhaust fan with 3-way ventilation switch
#10. Timer, vent switch and replacement air opens during firing
#11. Vent switch, combustion air, and interlocking replacement air
#12. Vent switch and interlocking replacement air Power Close
#12A. Vent switch and interlocking replacement air on a plug in exhaust fan
#12B. Vent switch and interlocking replacement air Power Open
#12C. High volume Kitchen Exhaust fan interconnected to a Forced Air Heating System, replacement air with inlet fan interlocked with a Power Open Damper