Home Support Colored Wiring Diagrams #8B - #8D2 #8B1

Colored Wiring Diagram #8B1

Two Forced Air Furnaces sharing a replacement air supply duct controlled by one fresh air damper with Power Open Damper
HMI Hoyme Manufacturing Inc. Special Note: Circuits are colored for clarification only and are not necessarily those found in actual installations.

Color Wiring Diagram #8B1

Diagram #8B1: Forced Air Furnace having a replacement air supply duct together with an exhaust fan controlled by a designated 24Vac ventilation switch.  

1. Replacement Air Control Damper, Power Close (HAC-0x11-OPC)
2. 24Vac Ventilation Switch.
3. 24Vac Relay Adaptor (ADP-0241-10A) to function as a control centre connected to the exhaust fan.

OPERATION: 
1. Furnace fires with thermostat signal and opens the replacement air damper.
2. 24Vac Ventilation Switch turns on Ventilation Fan, opens Replacement Air Damper and turns on Furnace Fan simultaneously.
3. Optional Switch (i.e. toggle switch, de-humidistat) allows full control of Replacement Air damper to open as required. 

N.B. Replacement Air Damper is not affected by the ‘Manual’ setting of the furnace fan.

1652-ld - Printed in Canada

Printer friendly (pdf)     - (Opens in a new window)

Last Updated (Friday, 30 December 2016 14:22)