Hoyme Colored Wiring Diagram #5A


120Vac Vent Switch, Combustion Air and Two Replacement Air Dampers (Power Close)(2 furnaces):

#5A. Two Furnaces, Combustion Air Damper (-SF2), Two Power Close Fresh Air Dampers(-PC) operating together, includes an Exhaust Fan and a 120vac Adaptor (ADP-1101-05A).

HMI Hoyme Manufacturing Inc. Special Note: Circuits are colored for clarification only and are not necessarily those found in actual installations. Combustion Air Damper Wires, however, are colored as shown.

Hoyme-colored-wiring-diagram-5a-image

Diagram #5A: Two Furnaces having a common combustion air and Two Replacement Air Supply Ducts together with and Exhaust Fan controlled by a designated Ventilation Switch and/or Bathroom Timer.

  1. Combustion Air Damper for two Furnaces (HOM-0x12-SF2)
  2. A Replacement Air Damper (HAC-0x10-OPC) for each Furnace
  3. 120Vac Ventilation Switch and/or Bathroom Timer
  4. Adaptor ADP-1101-05A on primary Furnace to act as a control center

OPERATION:

  1. Replacement Air Dampers are inter-connected to the Combustion Air Damper so that three Dampers open during firing of either or both Furnaces and close when firing stops
  2. Ventilation Switch and/or bathroom timer turns on Exhaust Fan, primary Furnace Fan and opens both HAC Dampers simultaneously
  3. Optional switch to each HAC Damper allows independent control of each Fresh Air Damper

N.B. Replacement Air Damper is not affected by the ‘Manual’ setting of the Furnace Fan.

Hoyme Colored Wiring Diagram #5A – Printer friendly (pdf)