Hoyme Color Wiring Diagram #6A6


120Vac Vent Switch, Adaptor 1101-05A and Replacement Air Damper, Power Close with ADP-0241-05A:

#6A6. Ventilation Switch and Fan, Two Adaptors (ADP-1101-05A) and (ADP-0241-05A), One Power Open Fresh Air Damper (-P\O) Opens during Venting and Furnace firing.

HMI Hoyme Manufacturing Inc. Special Note: Circuits are colored for clarification only and are not necessarily those found in actual installations. Combustion Air Damper Wires, however, are colored as shown.

Diagram #6A6:  Forced Air Furnace having a replacement air supply duct together with an exhaust fan controlled by a designated ventilation switch and/or bathroom timer.

  1. Replacement Air Control Damper (HAC-0x10-OPO) – (Power Open)
  2. Ventilation Switch and/or bathroom timer to supply Controlled 120Vac to furnace area.
  3. Relay Adaptor (ADP-1101-05A) to function as a control centre.
  4. Relay Adaptor (ADP-0241-05A) to open damper during heating cycle.

OPERATION:

  1. Replacement Damper opens to provide fresh air during the ventilation and heating cycle.
  2. Ventilation Switch and/or bathroom timer turns on Ventilation Fan, opens Replacement Air Damper and turns on Furnace Fan simultaneously.
  3. Damper will remain closed during manual furnace fan operation.

4. On/Off Switch connected to the Adaptors (as shown) allows manual control of the Replacement Air Damper to open as required.

Hoyme Colored Wiring Diagram #6A6 – Printer friendly (pdf)