Hoyme Colored Wiring Diagram #8B7


Forced Air Furnace with Power Open Replacement Air Duct with a Vent Switch that sends a 24Vac signal to Furnace area:

#8B7. Forced Air Furnace with Power Close Replacement Air Damper (HAC-0x10-OPC) and a Ventilation Switch/Timer that uses Adaptor (ADP-0242-05A)  to Open Replacement Air Damper with Ventilation Fan and also Opens during Furnace firing.

HMI Hoyme Manufacturing Inc. Special Note: Circuits are colored for clarification only and are not necessarily those found in actual installations. Combustion Air Damper Wires, however, are colored as shown.

Hoyme-colored-wiring-diagram-8b7-image

Diagram #8B7: Forced Air Furnace having a Replacement Air Supply Duct together with an Exhaust Fan controlled by a designated Ventilation Switch and/or Bathroom Timer that sends a 24Vac signal to the Furnace area.

  1. Replacement Air Control Damper, Power Open (HAC-0x10- OPC)
  2. Ventilation Switch and/or Bathroom Timer that sends Controlled 24Vac to Furnace area
  3. 24Vac Relay Adaptor (ADP-0242-05A) to function as a control center

OPERATION:

  1. Replacement Air Damper opens when Furnace fires with Thermostat signal
  2. Ventilation Switch and/or bathroom timer turns on Ventilation Fan, opens Replacement Air Damper and turns on Furnace Fan simultaneously. Note PC Damper is connected to Adaptor Terminal #4
  3. Optional Switch (i.e. toggle switch) allows full control of the Replacement Air Damper to open separately provided it is a Power Close type Damper

For Power Open Damper See Diagram #8A9

N.B. Replacement Air Damper is not affected by the Manual setting of the Furnace Fan.