Hoyme Colored Wiring Diagram #6C3


Vent Switch, Replacement Air – Power Open, interconnected with Exhaust Fan heating cycle and/or cooling cycle:

#6C3. Ventilation Switch, Two Adaptors (ADP-1102-TWP) and (ADP-0241-05A), One Power Open Replacement Air Damper (-PO) interconnected with Exhaust Fan, Heating and/or Cooling, Damper Opens with or without A/C and interconnected with A/C.

HMI Hoyme Manufacturing Inc. Special Note: Circuits are colored for clarification only and are not necessarily those found in actual installations. Combustion Air Damper Wires, however, are colored as shown.

Hoyme-colored-wiring-diagram-6c3-image

Diagram #6C3: Forced Air Furnace having a Replacement Air Supply Duct together with an Exhaust Fan controlled by a designated Ventilation Switch and/or Bathroom Timer.

  1. Use Replacement Air Control Damper (Power Open) – (HAC-0x10- OPO)
  2. Ventilation Switch and/or Bathroom Timer to supply controlled 120Vac to Furnace area
  3. Relay Adaptor (ADP-1102-TWP) to function as a control center
  4. Relay Adaptor (ADP-0241-05A) to function as a fresh air supply when Thermostat is set to the cooling cycle

OPERATION:

  1. Replacement Damper opens to provide fresh air during the heating and/or cooling cycle
  2. Ventilation Switch and/or bathroom timer turns on Ventilation Fan, opens Replacement Air Damper and turns on Furnace Fan simultaneously
  3. Damper will remain closed during manual Furnace Fan operation
  4. On/Off Switch connected to (ADP-1102-TWP) Terminal #2 (as shown) allows manual control of the Replacement Air Damper to open as required

Hoyme Colored Wiring Diagram #6C3 – Printer friendly (pdf)