Hoyme Colored Wiring Diagram #8A2


Replacement Air Damper Power Open with 120Vac Plug-In Vent Fan and Dampers controlled by Vent Switch:

#8A2. One Power Open Replacement Air Damper (-PO), One Adaptor (RADP-0241-10A) c/w 120vac controlled Receptacle, Two 24vac transformers, Two Power Open Air Dampers (HAC-0x10-SPO) c/w End Switches to Control Adaptor.

HMI Hoyme Manufacturing Inc. Special Note: Circuits are colored for clarification only and are not necessarily those found in actual installations. Combustion Air Damper Wires, however, are colored as shown.

Hoyme-colored-wiring-diagram-8a2-image

Diagram #8A2: Forced Air Furnace having a Replacement Air Supply Duct together with a plug-in type Exhaust Fan venting two bathrooms equipped with 24Vac Control Dampers.

  1. Replacement Air Control Damper, Power Open (HAC-0x10-OPO)
  2. Damper(s) with End Switch (HAC-0x10-SPO) controlled with a 24Vac Transformer from each bathroom
  3. 24Vac Relay Adaptor with Duplex Receptacle (RADP-0241-10A) to function as a control center supplying 120Vac for a plug-in type Exhaust Fan

OPERATION:

  1. Furnace fires with Thermostat signal
  2. 24Vac damper with end switch simultaneously turns on Furnace Fan, opens Replacement Air Damper and supplies 120Vac to the controlled side of the Duplex Receptacle for the plug-in type Exhaust Fan
  3. Optional Switch (i.e. toggle switch, de-humidistat) allows full control of Replacement Air Damper to open as required

N.B. Replacement Air Damper is not affected by the ‘Manual’ setting of the Furnace Fan

Hoyme Colored Wiring Diagram #8A2 – Printer friendly (pdf)