Hoyme Colored Wiring Diagram #8A4


Forced Air Furnace having a Combustion Air Supply Duct and also a Replacement Air Duct that serves as an air supply for a 120Vac Gas Dryer:

#8A4. Forced Air Furnace with Combustion Air Damper (HOM-0x12-SF2) and Power Close Replacement Air Damper (HAC-0x10-OPC) which supplies Replacement Air For 120vac Gas Dryer using  Adaptor (RADP-0241-S10A).

HMI Hoyme Manufacturing Inc. Special Note: Circuits are colored for clarification only and are not necessarily those found in actual installations. Combustion Air Damper Wires, however, are colored as shown.

Hoyme-colored-wiring-diagram-8a4-image

Diagram #8A4: Forced Air Furnace having a Combustion Air Supply Suct and also a Replacement Air Supply Duct that provides additional air for a 120Vac Gas Dryer and for the normal operation of the home.

  1. Combustion Air Damper (HOM-0x12-SF2) for two appliances
  2. 24Vac Relay Adaptor with a Duplex Receptacle and a Red Light on/off Switch (RADP-0241-S10A) to function as a control centre interlocked to120Vac supply for a plug-in type Gas Dryer
  3. Replacement Air Control Damper (Power Close) HAC-0x10-OPC (‘x’= diameter of Duct)

OPERATION:

  1. Combustion Air Damper is interlocked to open for Furnace firing and/or interlocked to open for Dryer operation
  2. The Gas Dryer is plugged into the Adaptor RADP-0241-S10A Receptacle and will operate only after the Red Light Switch is turned on and the Combustion Air Damper is in the Open position
  3. The HAC-0x10-OPC (Power Close) Damper will open and close simultaneously with the Combustion Air Damper. When the Dryer has completed its cycle, the Adaptor Red Light Switch is to be turned off allowing the Combustion Air Damper and the Replacement Air Damper to close

Note: Manual setting of the furnace fan does not affect the Combustion Air Damper operation.

This installation does not interfere with the operation of the Air Conditioner.