Hoyme Colored Wiring Diagram #8


24Vac Vent Switch and Replacement Air Opens During Firing:

#8. One 24vac Ventilation Switch, One Adaptor (ADP-0241-05A), One Power Close Replacement Air Damper (HAC-0x11-OPC) c/w Relay also Opens during Furnace firing.

HMI Hoyme Manufacturing Inc. Special Note: Circuits are colored for clarification only and are not necessarily those found in actual installations. Combustion Air Damper Wires, however, are colored as shown.

Hoyme-colored-wiring-diagram-8-image

Diagram #8: Forced Air Furnace having a Replacement Air Supply Duct together with an Exhaust Fan controlled by a designated Ventilation Switch and/or Bathroom Timer that sends a 24Vac signal to the Furnace area.

  1. Replacement Air Control Damper with Relay (HAC-0x11-OPC)
  2. Ventilation Switch and/or Bathroom Timer that sends Controlled 24Vac to Furnace area
  3. 24Vac Relay Adaptor (ADP-0241-05A) to function as a control center

OPERATION:

  1. Replacement Air Damper opens to provide fresh air during Furnace firing
  2. Ventilation Switch and/or Bathroom Timer turns on Ventilation Fan, opens Replacement Air Damper and turns on Furnace Fan simultaneously
  3. Optional Switch (i.e. toggle switch, timer, de-humidistat) allows full control of Replacement Air Damper to open provided it is a PC type with a Relay

N.B. Replacement Air Damper is not affected by the ‘Manual’ setting of the Furnace Fan

Hoyme Colored Wiring Diagram #8 – Printer friendly (pdf)