Hoyme Colored Wiring Diagram #8A9


Forced Air Furnace with Power Open Replacement Air Duct with a Vent Switch that sends a 24Vac signal to Furnace area:

#8A9. Forced Air Furnace With Power Open Replacement Air Damper (HAC-0x10-OPO) and a Ventilation Switch/Timer that uses Adaptor (ADP-0242-05A)  to open Replacement Air Damper with Ventilation Fan and also Opens during Furnace firing.

HMI Hoyme Manufacturing Inc. Special Note: Circuits are colored for clarification only and are not necessarily those found in actual installations. Combustion Air Damper Wires, however, are colored as shown.

Hoyme-colored-wiring-diagram-8a9-image

Diagram #8A9: Forced Air Furnace having a Replacement Air Supply Duct together with an Exhaust Fan controlled by a designated Ventilation Switch and/or Bathroom tTimer that sends a 24Vac signal to the fFurnace area.

  1. Replacement Air Control Damper, Power Open (HAC-0x10- OPO)
  2. Ventilation Switch and/or bathroom timer that sends Controlled 24Vac to Furnace area
  3. 24Vac Relay Adaptor (ADP-0242-05A) to function as a control center

OPERATION:

  1. Replacement Air Damper opens when Furnace fires with Thermostat signal
  2. Ventilation Switch and/or bathroom timer turns on Ventilation Fan, opens Replacement Air Damper and turns on Furnace Fan simultaneously. Note: PO Damper is connected to Adaptor Terminal #5
  3. Optional Switch connected between terminal #4 and #5 of the adaptor allows full control of Replacement Air Damper to open as required

N.B. Replacement Air Damper is not affected by the Manual setting of the Furnace Fan.

Hoyme Colored Wiring Diagram #8A9 – Printer friendly