Hoyme Colored Wiring Diagram #8B


24Vac vent Switch with Relay, Replacement Air Damper – Power Close:

#8B. Forced Air Furnace With Power Close Replacement Air Damper (HAC-0x11-OPC) c/w Relay and a Ventilation Switch/Timer that uses Adaptor (ADP-0241-05A) to Ventilate and also Open During Furnace firing.

HMI Hoyme Manufacturing Inc. Special Note: Circuits are colored for clarification only and are not necessarily those found in actual installations. Combustion Air Damper Wires, however, are colored as shown.

Hoyme-colored-wiring-diagram-8b-image

Diagram #8B: Forced Air Furnace having a Replacement Air Supply Duct together with an Exhaust Fan controlled by a designated Ventilation Switch and/or Bathroom Timer together with a 120Vac Relay that sends a 24Vac signal to the Furnace area.

  1. Replacement Air Control Damper, Power Close (HAC-0x11-OPC)
  2. Ventilation Switch and/or Bathroom Timer
  3. 24Vac Relay Adaptor (ADP-0241-05A) to function as a control center

OPERATION:

  1. Furnace fires with Thermostat signal
  2. Ventilation Switch and/or Bathroom Timer turns on Ventilation Fan, opens Replacement Air Damper and turns on Furnace Fan simultaneously
  3. Optional Switch (i.e. toggle switch, timer, de-humidistat) allows full control of Replacement Air Damper to open as required

N.B. Replacement Air Damper is not affected by the ‘Manual’ setting of the Furnace Fan.

Hoyme Colored Wiring Diagram #8B – Printer friendly