HMI Hoyme TMADP – 1102 – TPX
This TMADP-1102-TPX Adaptor with two Relays and a 24Vac Interval Timer, together with a Central Ventilation Switch, acts as an automatic/manual control centre to simultaneously start a principal Exhaust Fan, turn on a Furnace Fan, and open a Fresh Air Inlet Damper (If used) .
Installation Instructions – Printer friendly (pdf)
Instructions for Timer alone – Printer friendly (pdf)
Wiring Diagrams used with the TMADP-1102-TPX:
- #9. Forced Air Furnace With Combustion Air Damper (HOM-0x11-SF1) and a Power Close Replacement Air Damper (HAC-0x10-OPC) that uses Adaptor (TMADP-1102-TPX) to Open Replacement Air Damper and Run Furnace Fan With Ventilation Switch and During Timer Intervals and Also Opens During Furnace Firing.
- #9A. Identical to #9 But Minus the Combustion Air Damper (HOM-0x11-SF1).
- #9A1. Identical to #9A But Power Open (Not Close) Fresh Air Damper (HAC-0x10-OPO)
- #9A2. Identical to #9A1 But Add Adaptor (ADP-1101-05A) Connected to Multiple Exhaust Fans.
- #9A4. Forced Air Furnace With Power Open Replacement Air Damper (HAC-0x10-OPO) and Two (or more) Exhaust Fans Controlled by Two (or more) Separate Double Pole Ventilation Switches Using Adaptor (TMADP-1102-TPX) and Adaptor (ADP-1102-TWP) to Open Replacement Air Damper and Run Furnace Fan With Any Ventilation Switch and During Timer Intervals and Also Opens During Furnace Firing.
- #9A5. Same as #9A4 But Uses a Power Close Fresh Air Damper (HAC-0x10-OPC).
- #9B. Forced Air Furnace With Power Close Replacement Air Damper (HAC-0x10-OPC) and a 3-Way Ventilation Switch That Uses Adaptor (TMADP-1102-TPX) to Open Replacement Air Damper and Run Furnace Fan With 3-Way Ventilation Switch in One Position But Only the Ventilation Fan in the Other Position and During Timer Intervals and Also Opens During Furnace Firing.
- #9B1. Same as #9B But Uses a Power Open Fresh Air Damper (HAC-0x10-OPO)
- #9C. Same as #9B But has a Designated Ventilation Switch Which Functions Fully and Also an Additional 3-Way Switch to Control Ventilation Fan Only.
- #9C1. Same as #9B1 But has a Designated Ventilation Switch Which Functions Fully and Also an Additional 3-Way Switch to Control Ventilation Fan Only.
- #10. Forced Air Furnace With Power Close Replacement Air Damper (HAC-0x11-OPC) c/w Relay and a Designated Ventilation Switch for Exhaust Fan That Uses Adaptor (TMADP-1102-TPX) to Open Replacement Air Damper and Run Furnace Fan With Ventilation Switch and During Timer Intervals and Also Opens During Furnace Firing.