HMI Hoyme ADP – 0241 – 05A
This Relay Adaptor may be used as an automatic switch having a 24Vac coil and 120Vac contact points to control a line voltage circuit for up to a 5 amp draw. i.e. Exhaust Fan. Adaptor can also be used 100% for 24Vac switching (See ADP-1101). Switching 24Vac Dampers and Thermostat Circuits use 5A type only (ADP-0241-05A). For 120Vac fan control, use 10A type only (ADP-0241-10A).
Installation Instructions – Printer friendly (pdf)
Wiring Diagrams used with the ADP-0241-05A:
- #3A. Combustion Air Damper (HOM-0x11-SF1) Interlocked to a Furnace and interconnected to a Power Close Fresh Air Damper (HAC-0x10-OPC).
- #6B1. Ventilation Switch and Large Exhaust Fan, Two Replacement Fresh Air Supply Ducts with Two Power Open Air Dampers (-PO), Both Dampers Open for Large Exhaust Fan, One Damper Opens During Furnace Firing.
- #6B2. Ventilation Switch and Exhaust Fan, One Replacement Fresh Air Supply Duct with Power Close Air Dampers (-PC), Open for Exhaust Fan, and During Furnace Firing.
- #6C2. Ventilation Switch, Two Adaptors (ADP-1102-TWP) and (ADP-0241-05A), One Power Open Replacement Air Damper (-PO) Interconnected With Exhaust Fan, Heating and/or Cooling, Damper Opens With or Without A/C But Not Interconnected with A/C.
- #6C3. Ventilation Switch, Two Adaptors (ADP-1102-TWP) and (ADP-0241-05A), One Power Open Replacement Air Damper (-PO) Interconnected With Exhaust Fan, Heating and/or Cooling, Damper Opens With or Without A/C and Interconnected with A/C.
- #7. One 24vac Ventilation Switch/Timer, Combustion Air Damper, One Adaptor (ADP-0241-05A), One Power Close Replacement Air Damper (-PC).
- #7A. Two 24vac Ventilation Switches/Timers and Two Exhaust Fans, Combustion Air Damper, One Adaptor (ADP-0241-05A), One Power Close Replacement Air Damper (-PC).
- #8. One 24vac Ventilation Switch, One Adaptor (ADP-0241-05A), One Power Close Replacement Air Damper (HAC-0x11-OPC) c/w relay Also Opens During Furnace Firing.
- #8A. One 24vac Ventilation Switch, One Adaptor (ADP-0241-05A), One Power Open Replacement Air Damper (HAC-0x10-OPO) Does Not Open During Furnace Firing.
- #8B. Forced Air Furnace With Power Close Replacement Air Damper (HAC-0x11-OPC) c/w Relay and a Ventilation Switch/Timer that uses Adaptor (ADP-0241-05A) to Ventilate and Also Open During Furnace Firing.
- #8C. Two Forced Air Furnaces Sharing a Replacement Air Duct with a Power Close Fresh Air Damper (HAC-0x11-OPC) c/w Relay Controlled by Adaptor (ADP-0241-05A).
- #8C5. Two Forced Air Furnaces Sharing a Replacement Air Duct with a Power Open Fresh Air Damper (HAC-0x10-OPO) With One Adaptor (ADP-1102-TWP) Interconnecting a Designated Ventilation Switch with One Furnace and a Second Adaptor (ADP-0241-05A) controlling the Second Furnace.
- #8C6. Two Forced Air Furnaces Sharing a Replacement Air Duct with a Power Close Fresh Air Damper (HAC-0x10-OPC) With One Adaptor (ADP-1102-TWP) Interconnecting a Designated Ventilation Switch with One Furnace and a Second Adaptor (ADP-0241-05A) controlling the Second Furnace.
- #8D. Two Forced Air Furnaces Sharing a Replacement Air Duct with a Power Close Fresh Air Damper (HAC-0x11-OPC) c/w Relay With Two Adaptors (ADP-0241-05A) Controlling the Replacement Air Damper for either furnace.
- #8D2. Forced Air Furnace With Combustion Air Damper (HOM-0x11-SF1) and a Power Close Replacement Air Damper (HAC-0x10-OPC) that uses Adaptor (ADP-0241-05A) to Open Replacement Air Damper During Both Heating and Cooling Cycles and to Open Combustion Air Damper During Furnace Firing.