HMI Hoyme ADP – 1101 – 05A
Adaptor control center combines 120Vac with 24Vac circuits. Interconnects the Thermostat Fan cycle, primary Exhaust Fan switch and the Furnace Circulating Fan. Fresh air Damper, if installed, also opens simultaneously with Exhaust Fan. Will not interfere with air conditioning controls. Comes with 120Vac Coil with 24Vac switching for 24Vac Dampers and Thermostat Circuits.
Installation Instructions – Printer friendly (pdf)
Wiring Diagrams used with the ADP-1101-05A:
- #5. 120vac Exhaust Fan With Adaptor (ADP-1101-05A) Causing a Power Close Fresh Air Damper to Open and Also Turn On a Furnace Fan Without Interfering with the Operation of the Combustion Air Damper.
- #5A. Two Furnaces, Combustion Air Damper (-SF2), Two Power Close Fresh Air Dampers (-PC) Operating Together, Includes an Exhaust Fan and a 120vac Adaptor (ADP-1101-05A).
- #5B. Two Furnaces, Combustion Air Damper (-SF2), Two Power Close Fresh Air Dampers With One (HAC-0x10-OPC) and One (HAC-0x11-OPC) c/w Relay, Each Damper Operating Separately With One to Each Furnace. Included is an Exhaust Fan and a 120vac Adaptor (ADP-1101-05A) That Opens the Fresh Air Damper and Turns On the Furnace Fan During Ventilation Only.
- #5B1. Two Furnaces, Combustion Air Damper (-SF2), Two Power Close Fresh Air Dampers (-PC) c/w Relays Operating Separately With One to Each Furnace, Also Open When Furnaces Fire. Included is an Exhaust Fan and a 120vac Adaptor (ADP-1101-05A) to Open the Main Fresh Air Damper and Start the Furnace Fan.
- #5B2. One Furnace, No Combustion Air Damper, Two 120vac Ventilation Fans, One Power Open Replacement Air Damper (-PO), One (ADP-1101-05A), One (ADP-1101-10AS).
- #5B3. Two 120vac Ventilation Fans, One Power Close Replacement Air Damper (-PC), One (ADP-1101-05A), One (ADP-1101-10AS).
- #5C. 120vac Two Double Pole Ventilation Fan Switches With Two Exhaust Fans, Combustion Air Damper and Power Close Replacement Air Damper (-PC).
- #6. 120vac Ventilation Fan Switch, Adaptor (ADP-1101-05A) and Power Close Replacement Air Damper c/w Relay (-PC) Opens During Furnace Firing.
- #6A. 120vac Ventilation Fan Switch, Adaptor (ADP-1101-05A) and Power Open Replacement Air Damper (-PO) Stays Closed During Furnace Firing.
- #6A1. Two 120vac Double Pole Ventilation Fan Switches and Two Exhaust Fans, Adaptor (ADP-1101-05A) and Power Open Replacement Air Damper (-PO).
- #6A2. Three 120vac Double Pole Ventilation Fan Switches and Exhaust Fans, Adaptor (ADP-1101-05A) and Power Close Replacement Air Damper c/w Relay (-PC), Opens During Furnace Firing.
- #6A3. Combustion Air Damper, Two Separate Ventilation and Exhaust Fans, Two Adaptors (ADP-1101-05A) and Power Close Replacement Air Damper (-PC).
- #6A4. Two 120vac Separate Ventilation Fans, Two Adaptors (ADP-1101-05A) and (ADP-1102-TWP), One Power Close Replacement Air Damper (-PC) Opens During Furnace Firing.
- #6A5. Two 120vac Ventilation Fans, Two Adaptors (ADP-1101-05A) and (ADP-1102-TWP), One Power Open Replacement Air Damper (-PO) Opens During Furnace Firing.
- #6B. Economizer Circuit System to Ventilate a Computer Server Room With 120vac Vent Switch and Fan, Adaptor (ADP-1101-05A), and One Power Close Air Damper (-PC).
- #6B1. Ventilation Switch and Large Exhaust Fan, Two Replacement Fresh Air Supply Ducts with Two Power Open Air Dampers (-PO), Both Dampers Open for Large Exhaust Fan, One Damper Opens During Furnace Firing.
- #6B2. Ventilation Switch with Exhaust Fan, Replacement Fresh Air Supply Duct with one Power Close Air Dampers (-PC), Damper Opens for Exhaust Fan, and during Furnace Firing.
- #9A1. Identical to #9A But Power Open (Not Close) Fresh Air Damper (HAC-0x10-OPO)
- #12D. Same as #12C But Also Includes a Separate Inlet Replacement Air Damper (HAC-0x10-OPO) and Adaptor (ADP-1101-05A) and Bathroom Fan with Designated Ventilation Switch, But Both Replacement Air Dampers Do Not Open During Furnace Firing.