#1A. Combustion Air Damper (HOM-0x11-SF1) Interlocked to a Furnace and Interconnected to a DHW with a Heat Limit Switch.
- #1B. DHW with Heat Limit Switch (HLS-1100) Interconnected to a Combustion Air Damper (HOM-0x11-SF1), No Furnace.
#2A. Combustion Air Damper (HOM-0x12-SF2) Interlocked to Two Furnaces and Interconnected to One Power Close Replacement Air Damper (HAC-0x10-OPC) Opens for Both Furnaces.
- #2A1. Combustion Air Damper (HOM-0x12-SF2) Interlocked to Two Furnaces and Interconnected to Two (HAC-0x10-OPC) Power Close Replacement Air Dampers That Open for either Furnace.
- #3. Combustion Air Damper (HOM-0x11-SF1) Interlocked to a Furnace and Interconnected to a Power Close Fresh Air Damper (HAC-0x10-OPC).
- #3A. Forced Air Furnace having a combustion fresh air supply duct and a replacement air supply duct. Fresh air damper opens for both A/C and heating cycle.
- #6A5. Two 120vac Ventilation Fans, Two Adaptors (ADP-1101-05A) and (ADP-1102-TWP), One Power Open Replacement Air Damper (-PO) Opens During Furnace Firing.
- #6A6. Ventilation Switch and Fan, Two Adaptors (ADP-1101-05A) and (ADP-0241-05A), One Power Open Fresh Air Damper (-PO) Opens During Venting and Furnace Firing.
- #6A7. Two Separate 120vac Ventilation Fans (One Primary and One Secondary), Two Adaptors (ADP-1102-TWP) and (ADP-1101-10AS), One Power Open Replacement Air Damper (-PO), Opens During Furnace Firing.
- #6A8. Two 120vac Ventilation Fan Switches (One Primary and One Secondary Ventilation Fans), Two Adaptors (ADP-1102-TWP) and (ADP-1102-10AS), One Power Close Replacement Air Damper (-PC), Opens During Furnace Firing.
- #6B2. Ventilation Switch and Fan, Two Adaptors (ADP-1101-05A) and (ADP-0241-05A), One Power Close Fresh Air Damper (-PC) Opens During Venting and Furnace Firing.
- #6B3. Forced Air Furnace having Replacement Air Supply Damper(Power Close- PC)
- #6B4. Forced Air Furnace having Replacement Air Supply Damper (Power Close- PC) with relay Opens during a call for heat and A/C
- #6B5. Forced Air Furnace paving Replacement Air Damper (Power Close – PC) with relay Opens during a call for heat and with Designated Ventilation Fan
#8A8. Forced Air Furnace With Power Open Replacement Air Damper (HAC-0x10-OPO) and MAC Power Close Air Supply Damper (MAC-0x11-SPC) Which Supplies Replacement Air For 120vac Gas Dryer Using adaptor (RADP-0241-S10A).
- #8A9. Forced Air Furnace With Power Open Replacement Air Damper (HAC-0x10-OPO) and a Ventilation Switch/Timer That Uses Adaptor (ADP-0242-05A) to Open Replacement Air Damper With Ventilation Fan and Also Opens During Furnace Firing.
- #9. Forced Air Furnace that has Combustion Air Damper (HOM-0x11-SF1) and a Power Close Replacement Air Damper (HAC-0x10-OPC) controlled by Adaptor (TMADP-1102-TPX) to Open Replacement Air Damper and run Furnace Fan with Ventilation Switch also during Timer Interval. Damper also Opens During Furnace Firing.