ADP – Interface Relay Adaptors – Complete List with Details


HMI ADP – Interface Relay Adaptors – Complete List with Details

Check out the pdf of our new ADP Brochure for general information on some of our more popular models of ADP Interface relay adaptors here


Quick links to Adaptors on this page:


Hoyme Millivolt dc Adaptors:


HMI Hoyme ADP – 0MV2 – S5A

Interlocking Relay Adaptor: for Combustion Fresh Air Inlet Damper – HOM – 24Vac; connects to 250mVdc to 100Vdc – 2 wire safety control system. Damper proves to be open before Furnace fires. Comes with 2 Relays, printed Circuit & Test/Run Switch. Also ideal for Commercial use.

Installation Instructions – Printer friendly (pdf)

Wiring Diagram used with the ADP-0MV2-S5A:

Hoyme-ADP-0mv2-s5a-wiring-diagram2

Hoyme 110Vac Coil Adaptors:


HMI Hoyme ADP – 1101 – 05A

Adaptor control center combines 120Vac with 24Vac Circuits. Interconnects the Thermostat fan cycle, Primary Exhaust Fan switch and the Furnace Circulating Fan. Fresh Air Damper, if installed, also opens simultaneously with Exhaust Fan. Will not interfere with air conditioning controls. Comes with 120Vac coil with 24Vac switching for 24Vac Dampers and Thermostat Circuits.

Installation Instructions – Printer friendly (pdf)

Wiring Diagrams used with the ADP-1101-05A:

Hoyme-Yellow-Box-csa2

HMI Hoyme ADP – 1101 – 10AS

This Adaptor ADP-1101-10AS is an Automatic Control Switch designed to operate with ADP-1101-05A or with ADP-1102-TWP to:

  1. Be connected to two Exhaust Fans, either one to operate from its own Exhaust Fan Switch but is interlocked to prevent the two Exhaust Fans from operating at the same time;
  2. To simultaneously turn on the Furnace Circulation Fan for either Exhaust Fan;
  3. To simultaneously open a Replacement/ Ventilation Damper (if used) for either Exhaust Fan.
    Note: If the Replacement Air Damper is to also open during the firing cycle of the furnace, replace ADP-1101-05A with ADP-1102-TWP.

Installation instructions – Printer friendly (pdf)

Wiring Diagrams used with the ADP-1101-10AS:

Hoyme-Yellow-Box-csa2

HMI Hoyme ADP – 1101 – 10AV

This Adaptor ADP-1101-10AV interfaces with Two Exhaust Fan Switches which control the same Exhaust Fan: one switch that controls one Exhaust Fan only and another switch that controls the same Exhaust Fan together with a Furnace Circulation Fan and a 24Vac Inlet Damper. It has two 120Vac Coil Relays with contact points switching both 120Vac and 24Vac Circuits. See Schematic Wiring Diagram for details.


Installation instructions – Printer friendly (pdf)

Wiring Diagram used with the ADP-1101-10AV:

Hoyme-Yellow-Box-csa2

Hoyme 24Vac Coil Adaptors


HMI Hoyme ADP – 0241 – 05A

This Relay Adaptor may be used as an automatic switch having a 24Vac coil and 120Vac contact points to control a line voltage Circuit for up to a 5 amp draw. i.e. Exhaust Fan. Adaptor can also be used 100% for 24Vac switching (See ADP-1101). Switching 24Vac Dampers and Thermostat Circuits use 5A type only (ADP-0241-05A). For 120Vac fan control, use 10A type only (ADP-0241-10A).

Installation Instructions – Printer friendly (pdf)

Wiring Diagrams used with the ADP-0241-05A:

Hoyme-Yellow-Box-csa2

HMI Hoyme ADP – 0242 – 05A

This Adaptor has two 24Vac Relays. The contact points of one relay can be used to control a 120Vac Circuit of up to 5 amp draw such as running a 120Vac Exhaust Fan.
This Adaptor can also be used 100% for 24Vac switching.

Installation instructions – Printer friendly (pdf)

Wiring Diagrams used with the ADP-0242-05A

Hoyme-Yellow-Box-csa2

HMI Hoyme ADP – 0243 – S5A

This 24Vac Relay Adaptor with three relays is designed to be interlocked to two separate 24Vac safety control appliance stats controlling one 24Vac Damper (HOM-0x11-SF1) proving to be open before one or both appliances fire separately or together. A third heating appliance can be added using a combustion air control damper (HOM-0x12-SF2) that has two separate Interlocking Circuits combined with the Adaptor.

Installation instructions – Printer friendly (pdf)

Wiring Diagrams used with the ADP-0243-S5A:

Hoyme-ADP-0243-S5A

HMI Hoyme ADP – 0244 – 05A

This Relay Adaptor (x2) is to be used in Tandem as a control center to operate one Furnace with two separate Thermostats to heat and cool two separate zones in a building. Two 24Vac Power Close Dampers are also required.

Installation instructions – Printer friendly (pdf)

Wiring Diagrams used with the ADP-0244-05A:

Hoyme-ADP-yellow-box2

HMI Hoyme ADP – 0241 – 10A

This Relay Adaptor may be used as an automatic switch having a 24Vac coil and 120Vac contact points to control a line voltage Circuit for up to a 10 amp draw.
i.e. Exhaust Fan Adaptor can also be used 100% for 24Vac switching (See ADP-1101). Switching 24Vac Dampers and Thermostat Circuits use 5A type only (ADP-0241-05A) and for 120Vac fan control, use 10A type only (ADP-0241-10A).

Installation Instructions – Printer friendly (pdf)

Wiring Diagrams used with the ADP-0241-10A:

Hoyme-Yellow-Box-csa2

HMI Hoyme RADP – 0241 – 10A

This Interface Adaptor comes with a Relay 24Vac Coil SPDT to develop a 10A contact capacity and a Relay 24Vac Coil DPDT to develop multiple contact points together with a split Duplex Receptacle. The split Receptacle provides a controlled, plus a continuous 120Vac power supply outlet. The two 24Vac Coils are connected in parallel and therefore act as one Relay. This Adaptor allows for a 24Vac Circuit such as a furnace safety Control Circuit or a 24Vac Damper with End Switch to control a 120Vac PLUG-IN Fan for ventilation, zone control or fresh air control.

Installation Instructions – Printer friendly (pdf)

Wiring Diagram used with the RADP-0241-10A:

Hoyme-RADP-0241-10a-photo2

HMI Hoyme RADP – 0241 – S10A

This interface Adaptor RADP-0241-S10A is an interlocking control device to safely supply fresh air for a Dryer/Damper/Furnace combination. The Adaptor has a manual red light switch that, when turned on, the Fresh Air Damper opens proving its position prior to Gas Dryer operation (Interlocked).

This Adaptor may be interlocked to Dampers:

  • HOM-0x11-SF1
  • HOM-0x12-SF2, secondary circuit
  • HAC/MAC-0x11-SPC
  • HAC/MAC-0x10-SPO

This Adaptor may also be interconnected to simultaneously turn on a Furnace Circulation Fan and open an HAC Replacement Air Damper, if used, on a Furnace return Plenum. Damper(s) remain open until the red light switch is manually turned off.

Installation Instructions – Printer friendly (pdf)

Wiring Diagrams used with the RADP-0241-S10A:


HMI Hoyme RADP – 0242 – S10A

This interface Adaptor RADP-0242-S10A is an interlocking control device to safely supply fresh air for a Dryer/Damper/Furnace combination. The Adaptor has a manual red light switch that, when turned on, the Fresh Air Damper opens proving its position prior to Gas Dryer operation (Interlocked).

This Adaptor may be interlocked to Dampers:
HOM-0x11-SF1
HOM-0x12-SF2, secondary circuit
HAC/MAC-0x11-SPC
HAC/MAC-0x10-SPO

This Adaptor may also be interconnected to simultaneously turn on a Furnace Circulation Fan and open an HAC Replacement Air Damper, if used, on a Furnace return Plenum. HAC Damper may also open during Furnace firing. Damper(s) remain open until the red light switch is manually turned off.

Installation Instructions – Printer friendly (pdf)

Wiring Diagrams used with the RADP-0242-S10A:

Hoyme-RADP-024-s10a-photo2

Hoyme 110Vac & 24Vac Coil Adaptors:


HMI Hoyme ADP – 1102 – TPX

This adaptor acts as a control center activated by a 120Vac Ventilation Switch to:

  • (1) Open a 24Vac Fresh Air Inlet Damper equipped with an End Switch
  • (2) Simultaneously turn on the Furnace Circulation Fan
  • (3) Turn on a 120Vac Exhaust Fan after Damper proves to be open (Interlocked)

Installation Instructions – Printer friendly (pdf)

Wiring Diagrams used with the ADP-1102-TPX:

Hoyme-Yellow-Box-csa2

HMI Hoyme ADP – 1102 – TWP

This Adaptor is an automatic switch to open a 24Vac Replacement/Ventilation Damper during the Ventilation cycle and/or during the firing cycle of the Furnace. By connecting the Adaptor 120Vac Relay Coil to the controlled line voltage of an Exhaust Fan and connecting the 24Vac Circuit to the Furnace Terminals, the Exhaust Fan, the Furnace Fan and the Inlet Damper will all operate simultaneously. The inlet Damper may also be connected to open during the firing cycle of the Furnace.

Installation Instructions – Printer friendly (pdf)

Wiring Diagrams used with the ADP-1102-TWP:

Hoyme-Yellow-Box-csa2

HMI Hoyme ADP – 1102 – TW5

This Adaptor ADP-1102-TW5 is an Automatic Relay Control Switch specifically designed, but not limited, to accommodate two separate Exhaust Fans in a dwelling interconnected to one furnace having a Replacement Air Duct and (if used) a Replacement Air Damper. A controlled 120Vac signal from one Exhaust Fan and/or a controlled 24Vac signal (or dry contacts) from a second Exhaust Fan will simultaneously turn on the Furnace Circulation Fan and open the Replacement Air Damper.

Installation instructions – Printer friendly (pdf)

Wiring Diagram used with the ADP-1102-TW5:

Hoyme-Yellow-Box-csa2

HMI Hoyme ADP – 1102 – 10A

120Vac Interlocking Relay Adaptor: for Combustion Fresh Air Inlet Dampers and Flue Dampers interlocking with Tankless Water Heaters. This Adaptor accommodates a safety control system that might differ from the load capacity (i.e circulating pump). Dampers prove to be open before fire starts.
Ideal for Residential and Commercial use.

Installation Instructions – Printer friendly (pdf)

Wiring Diagrams used with the ADP-1102-10A:

Hoyme-Yellow-Box-csa2

HMI Hoyme ADP – 1102 – S5A

120Vac Interlocking Relay Adaptor: for Combustion Fresh Air Inlet Dampers and Flue Dampers using 120Vac safety control systems. Dampers prove to be open before fire starts. This Adaptor, with two Relays, senses a line voltage stat, proves a 24Vac Damper to be open and then sends a signal back to line Stat Circuit for firing. Comes with 120Vac relay, 24Vac relay & Test/Run switch. Also ideal for Commercial use.

Installation Instructions – Printer friendly (pdf)

Wiring Diagrams used with the ADP-1102-S5A:

Hoyme-ADP-0mv2-s5a-wiring-diagram2

HMI Hoyme RADP – 1102 – TPX

This Adaptor (RADP-1102-TPX), by using a Manual Switch or Timer, acts as an automatic con­trol cen­ter to:

  • 1) Open a 24Vac Motorized Air Inlet Dampe­r with End Switch (interlocked) which proves to be open
  • 2) Before the plug-in Exhaust Fan turns on and
  • 3) Simultaneously turns on a Furnace Circulation Fan

It has two Relays and a split Duplex Receptacle; one side live and the other side controlled. If using a Damper without an End Switch, a jumper wire is required between Adaptor Terminals #1 and #4. As a result, the Fans and the Damper will not be interlocked but will operate simultaneously.

Installation Instructions – Printer friendly (pdf)

Wiring Diagram used with the RADP-1102-TPX:

Hoyme-RADP-0241-10a-photo2

HMI Hoyme TMADP – 1102 – TPX

This TMADP-1102-TPX adaptor with two Relays and a 24Vac Interva­l Timer, together with a Central Ventila­tion Switch, acts as an automatic/manual con­trol cen­ter to simultaneously start a principal Exhaust Fan, turn on a Fur­nace Fan, and open a Fresh Air Inlet Dampe­r (If used)

Installation Instructions – Printer friendly (pdf)

Instructions for Timer alone

Instructions for Timer alone – Printer friendly (pdf)

Wiring Diagrams used with the TMADP-1102-TPX:

Hoyme-TMADP-1103-twp-wiring-photo2

HMI Hoyme TRADP – 1102 – TPX

This TRADP-1102-TPX adaptor includes two Relays, a 24Vac Interva­l Timer and a Split Duplex Receptacle. This Adaptor acts as an automatic con­trol cen­ter to simultaneously turn on a Fur­nace Fan, start a plug-in type Exhaust Fan and open a 24Vac Motorized Air Inlet Dampe­r. The duplex receptacle is split to accommodate a live outlet and a controlled 120Vac outlet for the Exhaust Fan. A designated Ventilation Switch may be added for direct control to override the timer.

Installation Instructions – Printer friendly (pdf)

Instructions for Timer alone

Instructions for Timer alone – Printer friendly (pdf)

Wiring Diagrams used with the TRADP-1102-TPX:

Hoyme-Yellow-Box-Timer-plugs

HMI Hoyme ADP – 1103 – TPX

This ADP-1103-TPX Adaptor with 3 relays acts as a control center activated by a manual 120Vac Ventilation Switch to:

  • (1) Open a 24Vac Fresh Air Inlet Damper equipped with an end switch
  • (2) Simultaneously turn on the Furnace Fan
  • (3) Turn on a 120Vac Exhaust Fan after Damper proves to be open (interlocked) and
  • (4) In addition, the Inlet Damper will also open during Furnace firing

Installation Instructions – Printer friendly (pdf)

Wiring Diagrams used with the ADP-1103-TPX:

Hoyme-Yellow-Box-csa2

HMI Hoyme ADP – 1103 – TWP

This Adaptor is an automatic switch to actuate a 24Vac Replacement/Ventilation Damper to open during the exhausting of air or during the firing cycle of the Furnace. By connecting the Adaptor 120Vac Relay Coil to the controlled line voltage of an Exhaust Fan and connecting the 24Vac Circuit to the Furnace terminals, the Exhaust Fan, the Furnace Fan and the Inlet Damper will all operate simultaneously. The Replacement Damper will also operate individually during the firing of the Furnace.

Installation Instructions – Printer friendly (pdf)

Wiring Diagram used with the ADP-1103-TWP:

Hoyme-Yellow-Box-csa2

HMI Hoyme ADP – 1103 – TW5

This Adaptor ADP-1103-TW5 is an automatic control switch which is designed but not limited to accommodate two separate Exhaust Fans in a dwelling having one Furnace and (if used) a Replacement Air Damper. A controlled 120Vac signal from one Exhaust Fan and/or a 24Vac signal (or dry contacts) from a second Exhaust Fan will simultaneously turn on the Furnace Circulation Fan and open the Replacement Air Damper. Added is a Relay to also open the damper during Furnace firing.

Installation instructions – Printer friendly (pdf)

Wiring Diagrams used with the ADP-1103-TW5:

Hoyme-Yellow-Box-csa2

HMI Hoyme TMADP – 1103 – TWP

This TMADP-1103-TWP adaptor with three Relays and a 24Vac Interval Timer, together with a Central Ventilation Switch, acts as an automatic/manual control center to simultaneously turn on a principal Exhaust Fan, turn on a Furnace Fan, and open a Fresh Air Inlet Damper (If used). In addition, this adaptor also opens the Inlet Damper during Furnace firing.

Installation Instructions – Printer friendly (pdf)

Instructions for Timer alone

Instructions for Timer alone – Printer friendly (pdf)

Wiring Diagram used with the TMADP-1103-TWP:

Hoyme-TMADP-1103-twp-wiring-photo2

Hoyme Adaptor Switches with No Relays:


HMI Hoyme ADP – 0240 – 1WS

This ADP-0240-1WS Adaptor acts as a ready-built On/Off Switch for a variety of uses. This provides direct control to manually open Power Closed Dampers as needed. As well as any number of situations requiring a ready-made 24Vac On/Off Switch Box with terminal strips for ease of installation. For example, manual Furnace Fan control.

Installation Instructions – Printer friendly (pdf)

Wiring Diagram used with the ADP-0240-1WS:

Hoyme-ADP-0240-1ws-photo2

HMI Hoyme ADP – 024T – S20VA

This ADP-024T-S20VA Adaptor is a ready-built 24Vac Transformer (20Va) with On/Off Switch for a variety of uses. This provides direct control to manually turn on or off the 24Vac Transformer as needed. It also comes with a ready-to plug-in cord for ease of installation.

Installation instructions- Printer friendly (pdf)

Wiring Diagram used with the ADP-024T-S20VA:

Hoyme-ADP-024t-s20va-photo2